Thank you for your interest in WE2555 available NSN part on NSN Sphere. Transformer Power is listed with the part number WE2555, and its manufacturer is Wems Inc. This NSN part is currently available for purchase through our website today, and you may begin the process by filling out the following RFQ form. By providing us with information such as what parts you need, when you need them by, and your target price, our team can present you with a personalized quote that has been specifically tailored to fit your individual needs and requirements. Once you have submitted your request, a dedicated account manager will review and reach out to you in 15 minutes or less to continue the purchasing process.
As a leading online distributor of NSN parts like WE2555, we provide customers access to an expansive database of new, used, and obsolete items that have been sourced from top global manufacturers such as Wems Inc. If you are facing an AOG situation or time constraint, we provide same-day delivery and expedited shipping on a number of items. Get started on the purchasing process for NSN 5950003483801 under FSC 5950 Coils and Transformers and experience how NSN Sphere can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-348-3801 Item Description: Transformer Power | 5950 | 003483801 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
We2555 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.530 INCHES MAXIMUM3.530 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.428 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.448 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP2.448 INCHES MAXIMUM ALL MOUNTING FACI |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 1.990 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.010 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP2.010 INCHES MAXIMUM ALL MOUNTING FACI |
ABMK | OVERALL WIDTH | 2.580 INCHES MINIMUM AND 2.580 INCHES MINIMUM AND 2.680 INCHES MAXIMUM2.680 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.148 INCHES MINIMUM 2ND GROUP AND 0.148 INCHES MINIMUM 2ND GROUP AND 0.165 INCHES MAXIMUM 2ND GROUP0.165 INCHES MAXIMUM 2ND GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENTTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA AND WYE-OPEN DELTA AND WYE-WYEWYE-WYE |
ADAU | BODY HEIGHT | 1.420 INCHES MAXIMUM1.420 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS155.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS4 ALL GROUPINGS |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUPTHREADED HOLE 1ST GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUPUNTHREADED HOLE 2ND GROUPUNTHREADED HOLE 2ND GROUPTHREADED HOLE 1ST GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT7 SECONDARY SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | W/RECTIFIER AND COLOR CODED LEAD |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP0.138 INCHES 1ST GROUP |
CRBZ | WINDING OPERATING CURRENT | 130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 230.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 33.00 DC |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY115.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 201.00 AC |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 33.00 DC VOLTS NOM |
CWJS | WINDING OPERATING VOLTAGE | 36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
FEAT | SPECIAL FEATURES | VOLTAGES AND CURRENTS HAVE BEEN RECTIFIED FOR THE FIRST SECONDARYVOLTAGES AND CURRENTS HAVE BEEN RECTIFIED FOR THE FIRST SECONDARY |
TEST | TEST DATA DOCUMENT | 07187-4010238 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
THSD | THREAD SERIES DESIGNATOR | UNC 1ST GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 31 WIRE LEAD |