Thank you for your interest in B8485 available NSN part on NSN Sphere. Filter Radio Freque is listed with the part number B8485, and its manufacturer is Spectrum Controls Inc. This NSN part is currently available for purchase through our website today, and you may begin the process by filling out the following RFQ form. By providing us with information such as what parts you need, when you need them by, and your target price, our team can present you with a personalized quote that has been specifically tailored to fit your individual needs and requirements. Once you have submitted your request, a dedicated account manager will review and reach out to you in 15 minutes or less to continue the purchasing process.
As a leading online distributor of NSN parts like B8485, we provide customers access to an expansive database of new, used, and obsolete items that have been sourced from top global manufacturers such as Spectrum Controls Inc. If you are facing an AOG situation or time constraint, we provide same-day delivery and expedited shipping on a number of items. Get started on the purchasing process for NSN 5915006566976 under FSC 5915 Filters and Networks and experience how NSN Sphere can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-656-6976 Item Description: Filter Radio Freque | 5915 | 006566976 | 0 | Y | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
B8485 | 2 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 4.810 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.600 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.060 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.560 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.241 INCHES MINIMUM AND 0.247 INCHES MAXIMUM |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+500.0 |
AFGA | OPERATING TEMP RANGE | -55.0/+85.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 5TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 6TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 1ST RADIO INTERFERENCE AND 4.0 VOLTS DC 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 2ND RADIO INTERFERENCE AND 4.0 VOLTS DC 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 3RD RADIO INTERFERENCE AND 4.0 VOLTS DC 3RD RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 4TH RADIO INTERFERENCE AND 4.0 VOLTS DC 4TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 5TH RADIO INTERFERENCE AND 4.0 VOLTS DC 5TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 6TH RADIO INTERFERENCE AND 4.0 VOLTS DC 6TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 07639 |
AHBP | INPUT TERMINAL IDENTIFICATION | MS3102A-24-25 |
AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AHCJ | FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0 |
AHCK | FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 3.0 AND 5.0 AND 20.0 AND 40.0 AND 65.0 AND 80.0 |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | NUT AND WASHER |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 THREADED STUD OUTPUT 2ND FUNCTION |
CQDZ | MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 250.0 VOLTS AT SEA LEVEL |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AND 400.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION AND 400.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION AND 400.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION AND 400.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQRG | BODY MATERIAL | METAL |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 800.0 VOLTS AT SEA LEVEL |
FEAT | SPECIAL FEATURES | SIX FILTERED FUNCTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
ZZZK | SPECIFICATION/STANDARD DATA | 07639-B8485 MANUFACTURERS SOURCE CONTROL |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote