Thank you for your interest in 8502991 available NSN part on NSN Sphere. Transformer Power is listed with the part number 8502991, and its manufacturer is Honeywell International Inc. This NSN part is currently available for purchase through our website today, and you may begin the process by filling out the following RFQ form. By providing us with information such as what parts you need, when you need them by, and your target price, our team can present you with a personalized quote that has been specifically tailored to fit your individual needs and requirements. Once you have submitted your request, a dedicated account manager will review and reach out to you in 15 minutes or less to continue the purchasing process.
As a leading online distributor of NSN parts like 8502991, we provide customers access to an expansive database of new, used, and obsolete items that have been sourced from top global manufacturers such as Honeywell International Inc. If you are facing an AOG situation or time constraint, we provide same-day delivery and expedited shipping on a number of items. Get started on the purchasing process for NSN 5950013343755 under FSC 5950 Coils and Transformers and experience how NSN Sphere can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-334-3755 Item Description: Transformer Power | 5950 | 013343755 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8502991 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 4.000 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.600 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.600 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 4.000 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 45.0 HERTZ MINIMUM SINGLE COMPONENT AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAU | BODY HEIGHT | 3.700 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 150.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 2.9 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 23.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.276 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 17.25 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 84.82 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 11.50 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 12.00 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 29.25 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
TEST | TEST DATA DOCUMENT | 07187-8502991 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 7 THREADED STUD |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote