Thank you for your interest in 25051 available NSN part on NSN Sphere. Transformer Power is listed with the part number 25051, and its manufacturer is Emerson Electric Co. This NSN part is currently available for purchase through our website today, and you may begin the process by filling out the following RFQ form. By providing us with information such as what parts you need, when you need them by, and your target price, our team can present you with a personalized quote that has been specifically tailored to fit your individual needs and requirements. Once you have submitted your request, a dedicated account manager will review and reach out to you in 15 minutes or less to continue the purchasing process.
As a leading online distributor of NSN parts like 25051, we provide customers access to an expansive database of new, used, and obsolete items that have been sourced from top global manufacturers such as Emerson Electric Co. If you are facing an AOG situation or time constraint, we provide same-day delivery and expedited shipping on a number of items. Get started on the purchasing process for NSN 5950008246874 under FSC 5950 Coils and Transformers and experience how NSN Sphere can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-824-6874 Item Description: Transformer Power | 5950 | 008246874 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
25051 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
CWJS | Winding Operating Voltage | 26.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | Winding Operating Voltage | 93.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | Winding Operating Voltage | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
AKPV | Mounting Facility Quantity | 4 SINGLE GROUP |
CRBZ | Winding Operating Current | 10.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
ACZB | Frequency Rating | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
CRBZ | Winding Operating Current | 580.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | Winding Operating Current | 1.7 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
TTQY | Terminal Type And Quantity | 9 TAB, SOLDER LUG |
BPLC | Winding Function And Quantity | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
ABTD | Mounting Slot Width | 0.187 INCHES NOMINAL SINGLE GROUP |
ACZC | Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | Winding Operating Voltage | 45.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
AARG | Reliability Indicator | NOT ESTABLISHED |
ADAT | Body Width | 1.625 INCHES MAXIMUM |
ADAQ | Body Length | 3.500 INCHES MAXIMUM |
AKNA | Inclosure Type | OPEN |
ADAU | Body Height | 3.000 INCHES MAXIMUM |
AXGY | Mounting Method | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 0.906 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote