Thank you for your interest in E13719 available NSN part on NSN Sphere. Transformer Power is listed with the part number E13719, and its manufacturer is Electro Engineering Works Inc. This NSN part is currently available for purchase through our website today, and you may begin the process by filling out the following RFQ form. By providing us with information such as what parts you need, when you need them by, and your target price, our team can present you with a personalized quote that has been specifically tailored to fit your individual needs and requirements. Once you have submitted your request, a dedicated account manager will review and reach out to you in 15 minutes or less to continue the purchasing process.
As a leading online distributor of NSN parts like E13719, we provide customers access to an expansive database of new, used, and obsolete items that have been sourced from top global manufacturers such as Electro Engineering Works Inc. If you are facing an AOG situation or time constraint, we provide same-day delivery and expedited shipping on a number of items. Get started on the purchasing process for NSN 5950007595851 under FSC 5950 Coils and Transformers and experience how NSN Sphere can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-759-5851 Item Description: Transformer Power | 5950 | 007595851 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
E13719 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE |
ACZX | WINDING SHIELDING METHOD | EXTERNAL INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.375 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.562 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.125 INCHES MAXIMUM |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 55.00 DC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 220.00 DC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 460.00 DC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 10 SOLDER STUD |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 125.0 MILLIAMPERES DC MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 160.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |