Thank you for your interest in 213955 1 available NSN part on NSN Sphere. Transformer Power is listed with the part number 213955 1, and its manufacturer is Dataproducts Inc. This NSN part is currently available for purchase through our website today, and you may begin the process by filling out the following RFQ form. By providing us with information such as what parts you need, when you need them by, and your target price, our team can present you with a personalized quote that has been specifically tailored to fit your individual needs and requirements. Once you have submitted your request, a dedicated account manager will review and reach out to you in 15 minutes or less to continue the purchasing process.
As a leading online distributor of NSN parts like 213955 1, we provide customers access to an expansive database of new, used, and obsolete items that have been sourced from top global manufacturers such as Dataproducts Inc. If you are facing an AOG situation or time constraint, we provide same-day delivery and expedited shipping on a number of items. Get started on the purchasing process for NSN 5950003858906 under FSC 5950 Coils and Transformers and experience how NSN Sphere can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-385-8906 Item Description: Transformer Power | 5950 | 003858906 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
213955 1 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ACZB | FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT63.0 HERTZ MAXIMUM SINGLE COMPONENT63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.880 INCHES MINIMUM AND 5.880 INCHES MINIMUM AND 5.880 INCHES MINIMUM AND 6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM5.000 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 8 ALL GROUPINGS8 ALL GROUPINGS8 ALL GROUPINGS |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGSTHREADED HOLE ALL GROUPINGSTHREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT6 SECONDARY SINGLE COMPONENT6 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES ALL GROUPINGS0.250 INCHES ALL GROUPINGS |
CRBZ | WINDING OPERATING CURRENT | 0.6 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES DC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 8.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.00 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 30.00 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 16.80 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.60 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY100.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY16.80 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.60 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.70 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY48.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ALL VOLTAGES ARE STATED AS OPEN CIRCUIT; ALL CURRENTS ARE STATED AS RECTIFIED; 1 PRIMARY,6 SECONDARY WINDINGS; SECONDARIES 5 & 6 ARE RATED 115VRMS |
THSD | THREAD SERIES DESIGNATOR | UNF ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 20 THREADED STUD |