Part No | Description | Part Type | QTY | RFQ |
---|---|---|---|---|
DIP12-1A75-13Q | dry reed relay, spst, momentary, 0.014a (coil), 16vdc (coil), 145mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
8512183152 | dry reed relay, spst, momentary, 0.029a (coil), 12vdc (coil), 351mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
HI05-1A66 | reed relays high insulation 10w, 200v, 5vdc dry reed relay, spst, momentary, 0.008a (coil), 5vdc (coil), 40mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
1324175016 | dry reed relay | reed relays | Avl | RFQ |
HF12-1B54-6 | dry reed relay, spst, momentary, 0.071a (coil), 12vdc (coil), 850mw (coil), 1.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
MRX24-1C71 | dry reed relay, spdt, momentary, 0.004a (coil), 24vdc (coil), 98mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP05-1C96-51D | dry reed relay, spdt, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
8505183003 | dry reed relay, spst, momentary, 0.104a (coil), 5vdc (coil), 521mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIL05-1C90-51FHR | dry reed relay, spdt, momentary, 0.011a (coil), 5vdc (coil), 56mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIL05-1A66-13D | dry reed relay | reed relays | Avl | RFQ |
BE48-2A85-P | dry reed relay, dpst, momentary, 0.005a (coil), 48vdc (coil), 228mw (coil), 1a (contact), 1000vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
HM05-1A69-06 | dry reed relay, spst, momentary, 0.167a (coil), 5vdc (coil), 833mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP12-1A72-11E | dry reed relay, spst, momentary, 0.014a (coil), 16vdc (coil), 145mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
HM05-1A69-04 | reed relays high volt reed relay a-no 50w 3v 5vdc dry reed relay, spst, momentary, 0.167a (coil), 5vdc (coil), 833mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
1305100211 | dry reed relay | reed relays | Avl | RFQ |
HE12-1A69 | dry reed relay | reed relays | Avl | RFQ |
DIP15-1A75-11F | dry reed relay, spst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP05-1C96-51F | dry reed relay, spdt, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
1305290063 | dry reed relay, spdt, momentary, 0.033a (coil), 5vdc (coil), 167mw (coil), 0.25a (contact), 175vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP12-2A72-21A | dry reed relay, dpst, momentary, 0.029a (coil), 16vdc (coil), 290mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
HM12-1B83-150 | reed relays high volt reed relay b-nc 50w 3v 12vdc dry reed relay, spst, momentary, 0.048a (coil), 12vdc (coil), 575mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP05-1A72-13D | dry reed relay, spst, momentary, 0.014a (coil), 7.5vdc (coil), 50mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIL-CL-1A81-15-15M | dry reed relay, spst, momentary, 0.5a (contact), 90vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
3305100571 | dry reed relay, spst, momentary, 0.005a (coil), 5vdc (coil), 25mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
SIL05-1A72 | electromechanical relay spst-no 1a 5vdc 500ohm through hole | other connectors | Avl | RFQ |
3212172712 | dry reed relay, spst, momentary, 0.012a (coil), 12vdc (coil), 144mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
1324100110 | dry reed relay | reed relays | Avl | RFQ |
DIL-CL-1A81-9 | electromechanical relay spst-no 0.5a 9ohm through hole | other connectors | Avl | RFQ |
SIL03-1A72-71D | relay reed spst 0.5a 3v dry reed relay, spst, momentary, 0.006a (coil), 3vdc (coil), 18mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP15-1B72-19D | dry reed relay, spst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
3324172172 | dry reed relay | reed relays | Avl | RFQ |
DIP05-1B66-19L | dry reed relay, spst, momentary, 0.01a (coil), 5vdc (coil), 50mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
3205172910 | dry reed relay, spst, momentary, 0.01a (coil), 5vdc (coil), 50mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
3215272121 | dry reed relay, dpst, momentary, 0.008a (coil), 15vdc (coil), 113mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP24-1A75-13M | dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
3305190151 | dry reed relay, spdt, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
HM05-1A83-08 | reed relays high volt reed relay a-no 50w 3v 5vdc dry reed relay, spst, momentary, 0.111a (coil), 5vdc (coil), 555mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
H12-1A69 | dry reed relay, spst, momentary, 0.052a (coil), 12vdc (coil), 620mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
HM05-1B69-06 | dry reed relay, spst, momentary, 0.111a (coil), 5vdc (coil), 555mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
9603180012 | dry reed relay | reed relays | Avl | RFQ |
DIL05-3A71-30L | dry reed relay | reed relays | Avl | RFQ |
1305100210 | dry reed relay | reed relays | Avl | RFQ |
DIP15-1A75-13Q | dry reed relay, spst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP05-1C90-51L | relay reed spdt 250ma 5v | signal relays up to 2 amps | Avl | RFQ |
DIP12-1A72-12L | relay reed spst 1a 12v | signal relays up to 2 amps | Avl | RFQ |
HF24-1A54-5 | dry reed relay, spst, momentary, 0.024a (coil), 24vdc (coil), 575mw (coil), 1.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP05-1A72-12LHR | dry reed relay, spst, momentary, 0.005a (coil), 5vdc (coil), 25mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
8805285200 | dry reed relay, dpst, momentary, 0.05a (coil), 5vdc (coil), 250mw (coil), 1a (contact), 1000vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIL05-1A71-11D | dry reed relay | reed relays | Avl | RFQ |
1924183110 | dry reed relay, spst, momentary, 0.034a (coil), 24vdc (coil), 822mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP15-1A72-13M | dry reed relay, spst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
8424569006 | dry reed relay, spst, momentary, 0.024a (coil), 24vdc (coil), 576mw (coil), 3a (contact), 10000vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP15-2A72-21Q | dry reed relay, dpst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIL-CL-1A81-15-18M | dry reed relay, spst, momentary, 0.5a (contact), 90vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP24-1C90-51S | dry reed relay, spdt, momentary, 0.012a (coil), 24vdc (coil), 288mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP05-2A72-21M | dry reed relay, dpst, momentary, 0.034a (coil), 7.5vdc (coil), 125mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
3303172071 | dry reed relay, spst, momentary, 0.006a (coil), 3vdc (coil), 18mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
BE05-2A85-M | dry reed relay, dpst, momentary, 0.068a (coil), 7.5vdc (coil), 227mw (coil), 1a (contact), 1000vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
BT12-2A66 | dry reed relay, dpst, momentary, 0.003a (coil), 12vdc (coil), 30mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP12-1A72-12LHR | dry reed relay, spst, momentary, 0.006a (coil), 12vdc (coil), 72mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
CRR05-1BS | dry reed relay, spst, momentary, 0.026a (coil), 5vdc (coil), 129mw (coil), 0.5a (contact), 170vdc (contact), surface mount-straight | reed relays | Avl | RFQ |
3224175019 | dry reed relay, spst, momentary, 0.012a (coil), 24vdc (coil), 288mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
3312185676 | dry reed relay | reed relays | Avl | RFQ |
HM12-1A83-06 | dry reed relay, spst, momentary, 0.048a (coil), 12vdc (coil), 575mw (coil), 3a (contact), 7500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
8524169152 | dry reed relay | reed relays | Avl | RFQ |
MK25-1A46-5000W | reed relays 1 form a spst-no atex push button | reed relays | Avl | RFQ |
DIP15-1C90-51D | dry reed relay, spdt, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
BE12-1A66-1B66-M | dry reed relay, dpst, momentary, 0.032a (coil), 12vdc (coil), 389mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIL05-2C90-63M | dry reed relay | reed relays | Avl | RFQ |
DIP12-1A31-16L | reed relays dry reed relay | reed relays | Avl | RFQ |
DIL12-2C90-60L | dry reed relay | reed relays | Avl | RFQ |
MRE24-2A79 | dry reed relay | reed relays | Avl | RFQ |
BE24-1C90-V | dry reed relay, spdt, momentary, 0.002a (coil), 24vdc (coil), 73mw (coil), 0.5a (contact), 175vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
8424569002 | dry reed relay | reed relays | Avl | RFQ |
MRX24-1C90 | dry reed relay, spdt, momentary, 0.004a (coil), 24vdc (coil), 98mw (coil), 0.24a (contact), 28vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
8805285104 | dry reed relay | reed relays | Avl | RFQ |
DIP24-1A72-13L | dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP24-1A75-13L | dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
RM05-4AS-4-4 | relay reed 4pst 300ma 5v | signal relays up to 2 amps | Avl | RFQ |
SIL05-1A75-71L | dry reed relay, spst, momentary, 0.025a (coil), 5vdc (coil), 125mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP15-1A75-13D | dry reed relay, spst, momentary, 0.009a (coil), 20vdc (coil), 115mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
SIL03-1A72-71M | dry reed relay, spst, momentary, 0.006a (coil), 3vdc (coil), 18mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP24-1A75-11Q | dry reed relay, spst, momentary, 0.014a (coil), 30vdc (coil), 290mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP05-1A72-10B | dry reed relay, spst, momentary, 0.014a (coil), 7.5vdc (coil), 50mw (coil), 1a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
3205010019 | dry reed relay, spst, momentary, 0.01a (coil), 5vdc (coil), 50mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
DIP12-1A75-10C | dry reed relay, spst, momentary, 0.014a (coil), 16vdc (coil), 145mw (coil), 0.5a (contact), 500vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
MS05-1A31-75L | relay reed micro sgl hi voltage reed relay 1 form a 5 v micro sil | relays i o modules | Avl | RFQ |
3324175171 | dry reed relay | reed relays | Avl | RFQ |
DIP05-1A72-12MHR | dry reed relay, spst, momentary, 0.005a (coil), 5vdc (coil), 25mw (coil), 0.5a (contact), 200vdc (contact), through hole-straight mount | reed relays | Avl | RFQ |
BE05-2A85-PHI | dry reed relay | reed relays | Avl | RFQ |
Low Price Warrantied inventory at competitive prices
Find it fast Search the world's largest inventory of electronic components by manufacturer, category or part number
Quality guaranteed We sell only warrantied and traceable parts
Get it fast All inventory ready to ship from our sellers
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote